室内気候研究所 文献抄録


潜熱蓄熱材を適用したダイレクトゲインシステムに関する実験的研究
(第1報)室温変動幅と補助暖房量抑制に及ぼす熱容量の影響

An Experimental Analysis Of Direct Gain System Applies To PCM(Phase Change Material)
Part1: The Influence Of The Thermal Mass On The Indoor Climate Control And The Heating Energy Consumption

金湖悠一郎(北海道職能大) 中野有(北海道職能大) 松川 侑矢(北海道職能大) 湊谷佳子(北海道職能大)  石戸谷裕二 (北海道職能大)

Yuichiro KANEKO*1, Yu NAKANO*1 , Yuya MATSUKAWA*1 ,
Yoshiko MINATOYA*1 , Yuji ISHIDOYA *1
*1 Hokkaido Polytechnic College

The authors were quantified the effective thermal capacity of the PCM interior material from the room temperature drop, using a lumped constant system. As the experimental results, the effective thermal capacity of the PCM interior material at the solid-liquid phase region be about five times compared to PB12 (mm) were revealed. On the other hand, the house that was applied the direct gain system with PCM interior material were constructed in Sapporo. From the measurement results at this housing in winter, the author confirm that the room temperature can be kept near 20℃, even when using a wood stove. At the same time, the relative humidity can be maintained above 40%.

スクリーンショット(2013-08-18 11.00.32).png
スクリーンショット(2013-08-18 11.00.42).png

ダブルスキン内に設置した蓄熱ブラインドによる日射利用空調システムに関する研究
(第2報)PCMを充填したアルミブラインドの効果に関する実験的検討

A Study on the Solar-Air-Condition System with PCM Window Shade in Double-Skin Façade
Part2: An Experiment on the Effect of the Alminum-Blade filled with Gelled-PCM

松川侑矢(北海道職能大) 金湖悠一郎(北海道職能大) 中野有(北海道職能大)湊谷佳子(北海道職能大)石戸谷裕二(北海道職能大)

Yuya MATSUKAWA*1 , Yuichirou KANEKO*1, Yu NAKANO*1 ,
Yosiko MINATOYA*1, Yuji ISHIDOYA *1
*1 Hokkaido Polytechnic College

This report shows the basic performance of the heat storage aluminum-blade filled with gelled n-paraffin (PCM window shade). The amount of the thermal storage was 114 (kJ/m) when filled with n-icosane. In addition, the PCM blind was installed in a double skin facade of the 1/3 office model, the temperature of the inner glass surface is decreased about 3℃. As a result of measuring the solar radiation transmission rate in the room installed external window shade, the author confirmed that the cooling load can be reduced about 12% by PCM window shade.

研究風景イメージ560_03.jpg
研究風景イメージ560_05.jpg


潜熱蓄熱材を充填した二重ガラスの性能と暖房負荷削減効果の定量化に関する実験
An Experiment On The Performance of Double Glazing Filled With Gelled PCM

湊谷佳子(北海道職能大) 金湖悠一郎(北海道職能大) 中野有(北海道職能大) 松川侑矢(北海道職能大) 石戸谷裕二 (北海道職能大)

Yoshiko MINATOYA*1, Yuichiro KANEKO*1, Yu NAKANO*1,
Yuya MATSUKAWA*1 , Yuji ISHIDOYA*1
*1 Hokkaido Polytechnic College

This paper shows about the thermal and optical property of the double glazing filled with the gelled n-paraffin. When the experiment was carried out using a test piece of 12mm in thickness, the light transmission rate of gelled PCM was about 0.7(-) in the liquid phase. Also the author installed the gelled PCM that was packed in a bag of aluminum to the test housing, and confirmed that the heating load is reduced by about 22% compared with the usual high-insulated and airtight housing in Hokkaido.

研究風景イメージ560_05.jpg
研究風景イメージ560_06.jpg


開口部の日射熱収支を考慮した設計支援システムの開発
A Development of a Housing Design Supporting Systemin Consideration the Heat Balance of the Window

中野有(北海道職能大) 金湖悠一郎(北海道職能大) 松川侑矢(北海道職能大)湊谷佳子(北海道職能大)石戸谷裕二(北海道職能大)
Yu NAKANO*1 , Yuichirou KANEKO*1 , Yuya MATSUKAWA*1,
Yosiko MINATOYA*1, Yuji ISHIDOYA *1
*1 Hokkaido Polytechnic College

In order to provide an architectural design that is suitable for creative activities in the planning and conceptual stage, the author introduced a server-client system to the heating load calculation program of the existing stand-alone. Annual heating load was calculated taking into account the influence of the thermal capacity of the room on the effective utilization rate of solar heat acquisition. This system enabled the interactive input and output from mobile devices, and I believe that makes possible the collaboration work between designers, engineers, and clients.